MD55D

This compact Flat model 5-valve manifold is designed to accommodate any DIN19213 Interface pressure transmitter.

This manifold is usually fitted directly on the instrument which is mounted on its own bracket.

This manifold is standard produced in AISI316 material, but “exotic” materials are also available.

Maximum working pressure is 420 Bar
Maximum temperature is 200°C

Connections

Vent and/or testports will always be 1/4″ threadsize, independent of process connection sizes.

For ordering information please consult the Model Code Wizard for port connection types available.

Pressure vs. Temperature Diagram

Design features

  • Self aligning metal seats
  • Compact Design
  • Non-rotating spindle tip
  • Metal seal between body and bonnet
  • Bonnet Locking pins
  • Safetyback seating T-Bar and Anti-Tamper operated valves
  • Full traceability of all materials
  • 100% pressure tested

Options

  • Anti tamper facility with a removable T-bar key to prevent unauthorized operation of the valve
  • Sour Gas Service
  • Available in Monel, Hastelloy, Duplex or NACE compliant materials.
  • High temperature up to 450°C
  • High pressure up to 680 Bar

Valve diagram

Description

Measuring range
see data sheet
Measuring principal
OFCEAS laser
ambient temperature
10°C ... +40°C
Possible interfaces
Ethernet, ModBus (TCP/IP, RS), analog, USB
Power Supply
110–230V AC / 50–60 Hz
Analog outputs
4 ... 20mA; max. load 500Ω
Detection limit
see parameter
Respons time
< 10 sec
Dimensions (H x W x D)
Rack 19inch, 4U or cabinet
Weight
20 kg (analyzer)

5-valve manifold (Double Isolate, Double Equalize, Vent) for an economical way of mounting Direct Mounted differential pressure transmitters. Mostly used in NON-winterizing applications with optional stainless steel 2”-pipe mounting bracket.

Downloads